The E8 Fixed is designed for blood/sperm separations at a fixed speed of 3500 rpm only (1534 g-force). The E8 Variable and E8 Digital will separate blood/sperm at 3500 rpm and can be slowed to separate other fluids at lower g-force, such as urine specimens as outlined by C.L.I.A. regulations.
High Heat Sterilization Cycle
Fully automatic 200°C sterilization cycle with a simple touch on the screen.
Effectiveness of high heat sterilization cycle is validated thru in-house laboratory test.
All components and accessories are designed to meet 200°C temperature requirement.
Complies with different international guideline requirements for dry heat sterilization such as U.S. and E.U. Pharmacopeias.
Everything is STANDARD. Avoid running cost on other external accessories and consumables just to perform decontamination / sterilization cycle.
The entire sterilization cycle period is 8 hours.
Latest Infrared CO2 Sensor Technology
CARBOCAP® technology for heat durability and long term stability.
CO2 probe remains inside the incubator chamber during sterilization cycle. This saves time and reduce the risk of cross contamination.
Water vapor, dust, other chemicals, change in temperature, humidity, other gases and pressure do not affect the performance of the IR sensor.
Internal pressure sensor improves accuracy and stability.
With full temperature and pressure compensation.
Sensor head is heated to prevent condensation.
Optimized Clean Chamber Design
New ribbed design chamber allows installation of shelves without screws or pilasters.
Minimize risk of contamination.
Easy maintenance.
Quick and easy to clean.
More chamber space.
Complete Security System
Multiple over-temperature protection system guarantee maximum sample, user and environment protection.
All electrical components are UL recognized.
Electrical circuit protection is in accordance with UL requirements.
PIN code prevents unauthorized access on screen menu and functions.
Magnetic Door Lock System
Manually locks during normal operation to protect samples.
Automatically locks during high heat sterilization cycle to protect users.
Inlet Door Latch function turns off pump, gas supply, and heating functions when the door is opened.
CelTouch Screen Control System
Big, clear, and easy-to-read parameter display
Easy to follow on-screen icon menus
Actual Data Graph, Data Logging functions, Event Logs and Alarm Functions are easily seen on the screen
Easy download of data log files using USB Write menu
Can be performed with gloved fingers
Multiple language selections: English, German, Spanish, French, Italian
Active Humidification System
In order to provide optimal environmental conditions for cell growth that requires specific relative humidity, the CelSafe® CO2 incubator with optional active humidity control allows user to actively control humidity from up to 95%. Natural humidification method is from 85% to 90%.
Water reservoir is located at the back of the chamber. No more water pan.
Heats up and maintain water reservoir based on RH control.
Water inlet valve is triggered by water level sensor.
IR Sensor Model with Stainless Steel Chamber
Model | Description |
---|---|
CLS-170B-8 | CelSafe® Incubator, 170 L, IR Sensor, CO2 Control, High Heat Sterilization, 230 VAC, 50/60 Hz |
CLS-170B-9 | CelSafe® Incubator, 170 L, IR Sensor, CO2 Control, High Heat Sterilization, 115 VAC, 50/60 Hz |
IR Sensor Model with Stainless Steel Chamber and Active Humidification
Model | Description |
---|---|
CLS-170B-8-RH | elSafe® Incubator, 170 L, IR Sensor, CO2 Control, High Heat Sterilization, Active Humidification, 230 VAC, 50/60 Hz |
CLS-170B-9-RH | CelSafe® Incubator, 170 L, IR Sensor, CO2 Control, High Heat Sterilization, Active Humidification, 115 VAC, 50/60 Hz |
Suppressed O2 Model with Stainless Steel Chamber
Model | Description |
---|---|
CLS-170T-8 | CelSafe® Incubator, 170 L, IR Sensor, CO2 Control, O2 Control, High Heat Sterilization, 230 VAC, 50/60 Hz |
CLS-170T-9 | CelSafe® Incubator, 170 L, IR Sensor, CO2 Control, O2 Control, High Heat Sterilization, 115 VAC, 50/60 Hz |
Suppressed O2 Model with Stainless Steel Chamber and Active Humidification
Model | Description |
---|---|
CLS-170T-8-RH | CelSafe® Incubator, 170 L, IR Sensor, CO2 Control, O2 Control, High Heat Sterilization, Active Humidification,230 VAC, 50/60 Hz |
CLS-170T-9-RH | CelSafe® Incubator, 170 L, IR Sensor, CO2 Control, O2 Control, High Heat Sterilization, Active Humidification,115 VAC, 50/60 Hz |
Options
COA-1002: CO2 Backup (Tank Switcher), Factory Installed
COA-1002-F: CO2 Backup (Tank Switcher), Field Installed
COA-2033-F: Sealed Inner Door Kit for 170 L (4 Glass Doors with Latches), Field Installed
COA-2038: Sealed Inner Door Kit for 170 L (4 Glass Doors with Latches), Factory Installed
COA-1007: N2 Backup (Tank Switcher), Factory Installed
COA-1007-F: N2 Backup (Tank Switcher), Field Installed
Accessory
COA-2034-F: Roller Base
COA-2035-F: Floor Stand 200 mm (8") Adjustable Feet
COA-2036-F: Floor Stand 700 mm (27.6")
COA-2005-F: 2-Stage Gas Regulator for CO2 / N2
CGA 320: CGA 320 Connector (US Standard)
BP-BS341#08-NT4: BP-BS34-#8-NT4 Connector (British Standard)
G5/8-RH: G5/8-RH Connector (China Standard)
OA-2037-F: Extra Stainless Steel Shelf
COA-2010-F: Electronic CO2 Analyzer (Worldwide), for CO2 / Temp Measurement
(with Temperature Probe)
COA-2016-F: Electronic CO2 Analyzer (Worldwide), for CO2 / O2 / Temp Measurement
(with Temperature Probe)
COA-2017-F: Electronic CO2 Analyzer (Worldwide), for CO2 / O2 / RH / Temp Measurement (with Temperature Probe)
COA-2011-F: IQ/OQ Documentation
COA-2015-F: Inner Door Shelving Kit
Voyager: Voyager Software Kit.